No hot water from a combi boiler: what to check

No hot water from a combi? Often it is low pressure, a frozen condensate pipe or a lockout you can clear. Safe checks first, then the faults for an engineer.

The short answer

If your combi boiler gives no hot water, check the power, the controls, the pressure gauge (around 1 bar cold on most models) and the display for a fault code, then reset once. In freezing weather, check for a frozen condensate pipe. If the radiators heat but the taps run cold, suspect the diverter valve, flow sensor or a scaled plate heat exchanger, which need an engineer.

Key points

  • Work out first whether you have no heating and no hot water, or heating but no hot water; they point to different faults.
  • Low pressure, a tripped fused spur, controls left on the wrong setting and a frozen condensate pipe are all user-level fixes.
  • Radiators warming up when you run a hot tap is a classic sign of a sticking diverter valve.
  • Hot water that starts hot then fades can mean limescale in the plate heat exchanger; Approved Document L asks for scale protection on combis in hard water areas.
  • Never take the casing off; parts inside a gas boiler are a job for an engineer on the Gas Safe Register.

A combi boiler heats water as you use it, so when it fails you find out the moment you turn on the shower. The fault might be something you can clear in five minutes, such as low pressure or a frozen condensate pipe, or a worn part inside the boiler that needs an engineer. This post gives you a diagnosis table, the safe checks to make in order, what it means when the heating works but the hot water does not, why hard water matters, and what to tell an engineer so the first visit fixes it.

How a combi makes hot water, and why that matters for the fault

A combi has no hot water cylinder. When you open a hot tap, cold mains water starts flowing through the boiler and a flow sensor tells the control board to fire the burner. A motorised diverter valve then switches the hot water from the boiler's own circuit away from the radiators and through a small plate heat exchanger, where it heats the mains water on its way to your tap.

That chain gives you a diagnosis shortcut. If nothing works at all, the boiler is not firing, and the likely suspects are power, gas, pressure or a lockout. If the heating works but the taps run cold, the burner is fine and the fault is somewhere in the hot water side: the sensor, the diverter valve or the heat exchanger.

Combi boiler hot water diagnosis table

Find the line that matches what you are seeing. The last column tells you whether it is a check you can make or a call for an engineer.

No hot water from a combi: symptom, likely cause and who fixes it
What you seeLikely causeWho fixes it
No heating, no hot water, display blankNo power, tripped fused spur or a board faultCheck power yourself; board fault is an engineer
No heating, no hot water, fault code showingLockout from low pressure, ignition or gas supplyCheck pressure and reset once; repeat lockouts need an engineer
Fault code in frost, gurgling from the boilerFrozen condensate pipeYou, by thawing the pipe outside
Heating works, taps cold, radiators warm when a tap runsDiverter valve sticking in the heating positionEngineer
Heating works, boiler does not light when a tap opensFlow sensor stuck or blockedEngineer
Hot at first, then lukewarm or surging hot and coldScaled plate heat exchanger or low mains flowEngineer; check cold mains flow yourself
Hot water at the taps but not the showerShower valve or cartridge, not the boilerPlumber
Only one tap runs coldTap cartridge or a blocked mixerPlumber

Safe checks to make before calling anyone

Work through these in order. Each is a user-level action that manufacturers expect homeowners to carry out, and none needs the boiler casing removed. Baxi's own checklist covers the same ground: the display, the timer and thermostat settings (opens in a new tab)1, the pressure, the fuse box, frozen pipes and a reset.

  1. Check the powerMake sure the boiler display is lit. If it is blank, check the fused spur next to the boiler and the consumer unit for a tripped switch. A power cut can also reset the clock on older timers.
  2. Check the gas supplyIf you have a gas hob, see whether it lights. If it does not, the problem is the supply or a prepayment meter, not the boiler.
  3. Check the controlsMake sure the hot water temperature dial or setting has not been turned down, that no holiday or eco mode is on, and that the programmer is not set to off.
  4. Read the pressure gaugeBaxi says the sweet spot for most boilers is 1 bar (opens in a new tab)1 cold, though your manual may give a different figure. If it is low, top up with the filling loop as your manual shows; our guide to reading boiler pressure has the details.
  5. Look for frost and gurglingIn freezing weather, a fault code with a gurgling sound can mean the condensate pipe outside has frozen. Thaw it as described below before you reset.
  6. Reset onceNote the fault code first, then press reset as your manual shows. If it locks out again, stop resetting and call an engineer with the code.

Frozen condensate pipe: the cold-weather lockout

Condensing boilers produce water as they run, which drains through a plastic condensate pipe to a drain, usually outside. In a hard frost the water in an exposed run can freeze, the boiler backs up and locks out, and you lose heating and hot water together. Vaillant says to listen for gurgling or bubbling sounds (opens in a new tab)2 and to look along the outside pipe for ice.

To thaw it, pour warm water along the pipe from a jug or watering can, or hold a hot water bottle against it. Vaillant warns against boiling water from a kettle (opens in a new tab)2, which can crack the pipe. Only do this on a pipe you can reach from the ground, then reset the boiler as your manual shows. Long-term, Vaillant advises lagging the outside run with pipe insulation.

Why does a combi boiler have heating but no hot water?

When the radiators get hot but the taps stay cold, the burner, fan and gas supply are working. The fault sits in the parts that switch the boiler into hot water mode, and all of them are inside the sealed case.

Diverter valve

The diverter valve swings the boiler's hot water between the radiators and the plate heat exchanger. When it sticks in the heating position, you get lukewarm or cold taps and the radiators warm up every time you run a tap, even in summer with the heating off. Baxi notes these valves do get stuck sometimes (opens in a new tab)1, especially on older boilers. A worn actuator can sometimes be replaced on its own, while a seized valve body means draining the boiler down.

Flow sensor

If the boiler does not react at all when you open a hot tap, the flow sensor may be stuck or blocked with debris or scale. In our experience, a quick test is to open the hot tap fully: if the boiler fires at full flow but not at a trickle, the sensor is struggling to detect low flow. The boiler also needs enough cold mains flow to trigger it, so if the cold taps are weak too, read our guide to low water pressure in the house.

Plate heat exchanger

Scale or sludge in the plate heat exchanger stops heat crossing from the boiler's circuit to your mains water. The classic sign is hot water that comes through properly for a minute, then fades or surges hot and cold, while the heating stays fine. The boiler may also cut out on overheat because heat cannot escape. A scaled plate can sometimes be descaled off the boiler, but replacement is often the more reliable fix.

Why hard water causes combi hot water faults

Hardness comes from dissolved calcium and magnesium, and the Drinking Water Inspectorate says it causes scaling in hot water systems (opens in a new tab)4 and appliances. In a combi the scale builds up fastest in the plate heat exchanger, where the mains water is heated, and scale or debris can also clog the flow sensor on the cold inlet.

This is why Approved Document L (in England; Wales has its own Part L guidance) says that in hard water areas, suitable measures should be taken to treat the hot water circuit of combination boilers (opens in a new tab)3 to reduce limescale. On a new or replacement combi in a hard water area, ask your installer what scale protection is going in. An inline scale reducer on the cold feed costs little next to a plate heat exchanger.

Local note

Water hardness around Gloucestershire

The Drinking Water Inspectorate's map of typical water hardness (opens in a new tab)6 (a 2009 Defra map) shows supplies across England and Wales in bands from soft to very hard, and readings vary from one supply to the next, Gloucestershire included. Approved Document L counts water above 200ppm of calcium carbonate as hard, so ask your water company for the figure at your postcode before deciding on scale protection.

Boiler not firing up at all

If there is no heating and no hot water, and the display shows a lockout that returns after one reset, the boiler is failing to light or to prove its flame. Common causes include a worn ignition or flame sensing electrode, a blocked condensate trap (one of the parts an annual boiler service cleans), a fan or gas valve fault and low gas pressure at the meter. All of these need the casing off and an engineer on the Gas Safe Register.

Keep resets to one or two. Repeated resets on a boiler that keeps locking out do not fix it, and a lockout is the boiler protecting itself. Note the code, the pressure reading and what happened before it stopped.

Safety first

If you smell gas or a CO alarm sounds

Stop troubleshooting. Put out any naked flames, do not smoke, and do not use electrical appliances or switch lights on or off (opens in a new tab)7. Turn off the gas at the meter control valve if you can reach it safely, open doors and windows, go outside and call the National Gas Emergency Service on 0800 111 999 (opens in a new tab)5. If a carbon monoxide alarm has gone off or anyone feels unwell, follow our guide to carbon monoxide symptoms and what to do.

Calling an engineer: what to tell them

An engineer can bring the right part on the first visit if you give them a clear picture. Have the make and model from the front or the data badge under the boiler, the fault code, the pressure reading, and whether the heating works. Say whether the radiators warm up when you run a tap, and whether the hot water fails straight away or after a minute.

Check that whoever comes is on the Gas Safe Register and that their ID card lists boilers. HSE says registered engineers carry ID cards showing which appliances (opens in a new tab)5 they can work on. If the boiler is old and this is the third breakdown in a winter, ask whether repair still makes sense; our guide to boiler lifespan helps with that decision.

When to call a professional

Leave these to an engineer

Replacing a diverter valve, flow sensor, plate heat exchanger, electrode, fan or control board all means opening the sealed case of a gas appliance. That is not a homeowner job, however many videos show it being done.

Still no hot water after the pressure, reset and condensate checks? Call 07858 305739 or send us the fault code and pressure reading so we can tell you straight whether the job is one for us. Diverter and sensor faults go through our boiler repair service, a leak from the boiler or pipework is one for our urgent plumbing call-outs, and a single cold tap or shower is a job for our plumbing repairs.

Sources and further reading

  1. What to check if you have no hot water (opens in a new tab), Baxi. User checks for display codes, timer and thermostat, pressure near 1 bar, fuse box, frozen pipes and reset; diverter valves do get stuck
  2. Getting ready for winter: your condensate pipe (opens in a new tab), Vaillant. Signs of a frozen condensate pipe; thaw with warm water or a hot water bottle; do not use boiling water; insulate the pipe
  3. Approved Document L, Volume 1: Dwellings (2021 edition incorporating 2023 amendments) (opens in a new tab), GOV.UK (Ministry of Housing, Communities and Local Government). Paragraph 8.8: in hard water areas, treat the hot water circuit of combination boilers to reduce limescale; glossary: hard water is greater than 200ppm of CaCO3
  4. Water hardness (hard water) (opens in a new tab), Drinking Water Inspectorate. Hardness comes from calcium and magnesium, depends on local geology, causes scaling in hot water systems; ask your water company; links the England and Wales hardness map used for the Gloucestershire note
  5. Gas safety frequently asked questions (opens in a new tab), Health and Safety Executive (HSE). Gas emergency number 0800 111 999 and what to do if you smell gas; registered engineers carry ID cards listing the appliances they can work on
  6. Map showing the rate of hardness in mg/l as calcium carbonate in England and Wales (opens in a new tab), Drinking Water Inspectorate. 2009 Defra/DWI map (Crown copyright 2009) of typical hardness of supplies in bands from soft (0 to 50 mg/l) to very hard (over 300 mg/l), varying locally
  7. Gas emergencies (opens in a new tab), Wales & West Utilities (gas emergency and distribution network for Gloucestershire). If you smell gas: call 0800 111 999, open windows and doors, turn off the gas at the emergency control valve if possible (not if the meter is in a cellar or basement), do not use electrical appliances or switch lights on or off, do not smoke or use naked flames

Sources checked on 4 November 2026.

About this guide

Written by the team at CLA Developments, who do plumbing, heating, building and tiling work across Gloucestershire and the Cotswolds, and reviewed by Alistair Hunt, who leads the team on site. Customers on Checkatrade (opens in a new tab) mention him by name for bathroom refits, tiling and plumbing repairs. The facts were checked against the sources listed above. This is general guidance, not a survey of your home. Gas work must be done by a Gas Safe registered engineer, new electrical circuits by a qualified electrician, and structural changes need a structural engineer and building control. Spotted something out of date? Email us and we will correct it.

FAQ

More questions

Can't see yours? Call or email and you'll speak to the people who do the work.

No, not in the way a cylinder does. A combi heats water as it flows, so it keeps going as long as the tap is open. What it cannot do is supply unlimited flow: run a shower and a bath tap at once and both may go lukewarm because the boiler has reached its maximum output. That is a sizing limit, not a fault.

Yes. An electric shower heats cold mains water with its own element, so it carries on when the boiler is off. A mixer shower takes hot water from the combi and will run cold.

It depends mostly on how far the tap is from the boiler, because the cold water sitting in the pipe has to run off first. A kitchen tap next to the boiler should run hot within seconds, while a bathroom at the far end of a long house can take noticeably longer. A sudden change from what you are used to is worth looking into.

Usually it is urgent rather than an emergency. It becomes an emergency if there is a gas smell, a carbon monoxide alarm, water leaking from the boiler near electrics, or someone vulnerable in the house without heating in cold weather. For a leak, isolate the water at the stopcock first, then get help.

Often the new fitting has a lower flow rate or a flow restrictor, and the combi's flow sensor is not detecting enough flow to fire fully. Thermostatic mixers can also hold the temperature down if the hot and cold supplies are unbalanced. Try opening the tap fully. If that brings the heat back, the fitting needs adjusting rather than the boiler.