Immersion heater guide: running times, settings and faults

A 3kW immersion heater takes at least 2 to 3 hours to heat a typical cylinder from cold. Timer settings, safe temperatures and a fault-finding table.

The short answer

An immersion heater is an electric element inside a hot water cylinder, like a large kettle element. A typical 3kW element takes at least two to three hours, often longer, to heat a 120 to 150 litre cylinder from cold, less for a top-up. Store water at 60°C, the temperature HSE guidance gives for controlling legionella, and use a timer rather than leaving it on.

Key points

  • Heat-up time depends on cylinder size and element power: at least 2 hours 20 minutes for 120 litres and 3 hours for 150 litres from cold with a 3kW element, and real cylinders take longer.
  • The HSE says hot water should be stored at 60°C or above to kill legionella; bacteria grow between 20°C and 45°C.
  • A timer that heats the cylinder once or twice a day beats leaving the switch on, which keeps reheating water you are not using.
  • Replacing a faulty element on an existing circuit is not notifiable electrical work in England, but a new circuit is.
  • On an unvented cylinder, only use the manufacturer's immersion heater with its built-in safety cut-out.

The immersion heater is the part of the hot water system most people only think about when something goes wrong: the boiler has packed up, the hot water has run out, or the switch light is on but the taps run cold. Used well, it is a dependable backup or, in homes without mains gas, the main way of heating water. This post covers how long it takes to heat a tank and how to set a timer and thermostat safely. It also has a table for working out why yours has stopped, and the line between a safe check and a job for an electrician.

What an immersion heater does and who needs one

An immersion heater is a looped metal element that screws into a threaded boss on a hot water cylinder and sits in the water. Electricity heats the element and a rod thermostat beside it switches it off once the water reaches temperature. Many domestic elements are rated at 3kW; the Heatrae Sadia Megaflo eco product guide (opens in a new tab)5, for example, lists its immersion heaters at 3kW.

Many cylinders have two. A long element from the top heats most of the tank, or a short top element heats only the upper part for a quick boost while a bottom element heats the whole cylinder on a cheaper overnight rate. If you have a gas or oil boiler and a cylinder, the immersion is usually a backup. If you have no gas, it may be doing the work every day.

Combi boilers heat water on demand and have no cylinder, so a home with a combi has no immersion heater. If your combi has stopped making hot water, see no hot water from a combi boiler instead.

Local note

Off-gas homes in the Cotswolds

Cotswold District Council notes (opens in a new tab)6 that many homes across the Cotswolds are off the gas grid. In those rural villages a cylinder heated by an immersion, an oil boiler or a heat pump is the normal set-up, so getting the timer and thermostat right makes a real difference to running costs.

How long does an immersion heater take to heat water?

The answer comes down to simple physics: how many litres you are heating, how far you are raising the temperature and how powerful the element is. The figures below are our own calculation for a 3kW element heating a full cylinder from 10°C cold mains up to 60°C, with no allowance for heat loss. Treat these as minimums. The Megaflo guide lists 158 minutes for its 145 litre direct model with one 3kW element to recover from a 70% draw-off, about half as long again as the same calculation gives, because real cylinders lose heat as they warm up.

Most of the time you are not heating from cold. After a few showers the bottom of the cylinder is cold and the top is still hot, so a top-up takes a fraction of these times. A short top element heats only the upper part, which gives you a bath's worth sooner but not a full tank.

Minimum time for a 3kW element to heat a full cylinder from 10°C to 60°C (no heat loss)
Cylinder sizeTypical homeMinimum time from cold
90 litresFlat or one bathroom, light useAt least 1 hour 45 minutes
120 litresSmall house, one bathroomAt least 2 hours 20 minutes
150 litresFamily house, bath and showerAt least 2 hours 55 minutes
210 litresTwo bathroomsAt least 4 hours
250 litresLarger house, several outletsAt least 4 hours 50 minutes

Why an old cylinder heats slowly

If yours takes far longer than the table suggests, the usual culprits are a thin or missing insulation jacket on an old copper cylinder, a scaled-up element, or a failed top or bottom element so only half the tank is being heated. In hard water areas scale builds on the element and insulates it from the water, which slows heating and can make it hiss or crackle.

How long should an immersion heater be on for?

Long enough to bring the cylinder up to temperature once or twice a day, and no longer. The thermostat stops the element overheating the water, but a switch left on all day keeps topping up heat that leaks out of the cylinder and pipes while nobody is using it.

A plug-in or wired immersion timer lets you heat the tank just before you need it: for example, an early morning slot ending before showers and an evening slot before baths or washing up. A boost button gives you a one-off hour or two without changing the programme.

If you are on a two-rate electricity tariff such as Economy 7, set the timer to heat the whole cylinder inside the cheaper overnight hours and keep the top element for boosts only. Check the exact off-peak hours with your supplier, because they vary and do not always match the clock on the meter.

  • Backup only: leave the timer or switch off, and boost when the boiler is out of action.
  • Main hot water source: one long overnight heat on off-peak, plus a short evening top-up if needed.
  • Solar panels: a diverter can send spare daytime generation to the immersion before it is exported.

What temperature should an immersion heater be set to?

Set the cylinder thermostat so water is stored at 60°C. The HSE's guidance on hot and cold water systems (opens in a new tab)1 says hot water should be stored at 60°C at least to kill legionella. The HSE's overview of legionnaires' disease (opens in a new tab)2 notes that water between 20°C and 45°C is suitable for the bacteria to grow, which is why a cylinder turned right down to save money is a false economy.

Manufacturers usually set the thermostat near this from the factory. The Megaflo eco product guide (opens in a new tab)5 says its immersion thermostat is factory set to about 60°C and adjustable between 12°C and 68°C, and warns not to remove the terminal cover without switching off the electrical supply first.

Stored water at 60°C will scald, so the safe answer for bath taps is a thermostatic mixing valve, not a cooler cylinder. For new homes and buildings converted into homes, Approved Document G requires the hot water supply to a bath to be limited to 48°C.

Safety first

Isolate before you touch the cover

The thermostat sits under the immersion cover with live terminals beside it. Switch off at the immersion switch and the circuit breaker before taking the cover off, and if you are not sure which breaker it is, leave adjustments to an electrician or heating engineer. Never bypass the thermal cut-out.

Immersion heater not working: find the fault

Work through the simple checks before calling anyone out. Most callouts turn out to be a timer, a tripped breaker or an element that has failed outright.

  1. Check the switch and timerMake sure the wall switch is on, its neon is lit, and the timer is not in an off period. Press boost to rule the programme out.
  2. Check the consumer unitLook for a tripped breaker or RCD. If it trips again as soon as the immersion comes on, stop and get it tested; that points to a failed element or a wiring fault.
  3. Give it timeRun it for an hour, then carefully feel the cylinder near the top. Faint warmth after an hour from cold is normal; stone cold suggests no power is reaching the element.
  4. Rule out the boiler controlsOn a cylinder heated by a boiler as well, check the programmer is not set to heating only, so you know which heat source has actually stopped.
  5. Call it inIf the checks pass and there is still no heat, the element, thermostat or cut-out has probably failed and needs testing with the power isolated.
Common immersion heater faults and what they usually mean
SymptomLikely causeWhat to do
No hot water, switch light onFailed element or tripped cut-outIsolate and have the element tested
Breaker or RCD trips when it switches onElement breaking down to earthLeave it off and call an electrician or plumber
Hot water runs out fastOnly the top element working, or set too lowCheck both elements and the thermostat setting
Hissing, crackling or bangingScale on the elementDescale or replace the element
Water far too hot or steamingThermostat stuck onSwitch off at once and call an engineer
Scorched or very hot switchLoose connection or undersized switchSwitch off at the breaker and call an electrician

Is it cheaper to heat water with an immersion or a gas boiler?

An immersion turns almost all the electricity it uses into heat in the water, so it is efficient at the point of use. The catch is the price of the energy. Ofgem's price cap unit rates (opens in a new tab)7 show a unit of electricity costing several times as much as a unit of gas, so even allowing for boiler losses, a working gas boiler generally heats water more cheaply than an immersion on a standard rate. Rates change every quarter, so check the current figures on the Ofgem page and your own bill.

What changes the sums is the tariff and the alternatives. Off-peak electricity narrows the gap, solar diverters can make some of it free, and heat pumps move heat into the cylinder rather than making it from scratch, so they use much less electricity for the same hot water. Compare the unit rates on your own bills rather than trusting a national average.

If you are off the gas grid and relying on an immersion every day, it is worth talking to us about a heat pump with a cylinder sized to match. Our guide to heat pumps in older homes covers what tends to change in a period house.

Replacing an immersion heater: what the rules say

Swapping a failed element is plumbing and electrical work in one. The cylinder has to be isolated and drained below the boss, the old element unscrewed with a long box spanner, which can twist a thin old copper cylinder if it is seized, and the new one fitted with a fresh washer before refilling and testing.

On the electrical side, Approved Document P (opens in a new tab)3 says replacements, repairs and maintenance are not notifiable, while a new circuit is. So a like-for-like element on the existing supply does not need building control. Adding an immersion where there was none usually means running a new dedicated circuit, and a new circuit is notifiable, as is replacing the consumer unit or altering circuits in a special location such as a bathroom. Whoever does the work should still test the circuit afterwards. These rules are for England; Wales has its own Approved Document P.

Approved Document G (opens in a new tab)4 asks a vented cylinder heated directly by an immersion to have either a non-self-resetting energy cut-out or a temperature relief valve, and unvented cylinders go further: each heat source, including each immersion, should have its own non-self-resetting cut-out, alongside a factory-fitted temperature and pressure relief valve. The Megaflo guide also says replacement parts should be authorised spares fitted by a competent person. Do not fit a generic element from a DIY shop into a sealed, mains pressure cylinder. Our post on vented and unvented cylinders explains how to tell which you have.

When to call a professional

When to hand it over

Call a professional for a breaker that keeps tripping, a scorched switch, water that is far too hot, any work on an unvented cylinder, or a seized element on an old copper tank. Our plumbing repair team can drain, replace and recommission the cylinder in one visit.

If your immersion has stopped, keeps tripping or you want it on a sensible timer, our heating and hot water engineers can test it and give you a written quote first. Get in touch and we reply within one working day.

Sources and further reading

  1. Hot and cold water systems: things to consider (opens in a new tab), Health and Safety Executive. Hot water should be stored at 60°C at least to kill legionella
  2. Legionnaires' disease: what is it? (opens in a new tab), Health and Safety Executive. Water between 20°C and 45°C is suitable for legionella growth
  3. Approved Document P: Electrical safety, dwellings (2013 edition) (opens in a new tab), GOV.UK. New circuits are notifiable; replacements, repairs and maintenance are not
  4. Approved Document G: Sanitation, hot water safety and water efficiency (2015 edition with 2016 and 2024 amendments) (opens in a new tab), GOV.UK. Non-self-resetting energy cut-out for direct heat sources; 48°C limit for bath hot water in new dwellings
  5. Megaflo eco unvented direct and indirect hot water cylinders: product guide (opens in a new tab), Heatrae Sadia (manufacturer document, installer-hosted copy). 3kW immersion rating, thermostat factory set about 60°C and adjustable 12°C to 68°C, isolate before removing cover, authorised spares by a competent person
  6. Heat pump grant increase could benefit off-grid homes in the Cotswolds (opens in a new tab), Cotswold District Council. Many homes across the Cotswolds are off the gas grid
  7. Energy price cap unit rates and standing charges (opens in a new tab), Ofgem. Electricity unit rate under the price cap is several times the gas unit rate (October to December 2026)

Sources checked on 4 November 2026.

About this guide

Written by the team at CLA Developments, who do plumbing, heating, building and tiling work across Gloucestershire and the Cotswolds, and reviewed by Alistair Hunt, who leads the team on site. Customers on Checkatrade (opens in a new tab) mention him by name for bathroom refits, tiling and plumbing repairs. The facts were checked against the sources listed above. This is general guidance, not a survey of your home. Gas work must be done by a Gas Safe registered engineer, new electrical circuits by a qualified electrician, and structural changes need a structural engineer and building control. Spotted something out of date? Email us and we will correct it.

FAQ

More questions

Can't see yours? Call or email and you'll speak to the people who do the work.

You can, and the thermostat will stop it boiling the water, but it is the most expensive way to run it. With the switch left on, the element keeps replacing heat lost from the cylinder and pipes all day and night, even when nobody needs hot water. A timer that heats the cylinder before the times you actually use it gives you the same hot water for less electricity.

Yes, as long as your cylinder has one fitted and it is wired to its own supply. That is one of the main reasons most cylinders are fitted with an immersion heater. Switch it on or press boost and allow a couple of hours from cold. If your boiler fault is a pressure problem rather than a breakdown, our guide to boiler pressure may get it going again without an engineer.

A 3kW element uses 3 kilowatt-hours for every hour it is actually heating. That is a large load compared with lights or a television, which is why it sits on its own circuit. How much it costs you depends on how long it runs, how well the cylinder is insulated and your tariff. A well lagged cylinder on a timer uses far less than one left switched on with a thin jacket.

A switch that feels warm after hours of use can be normal, but one that is hot, discoloured, buzzing or smells of burning is a warning sign. Common causes are a loose terminal or a switch not rated for the load. Turn the circuit off at the consumer unit and have an electrician look at it before using the immersion again.

There is no fixed lifespan. It depends mostly on water hardness and how hard the element is worked. Elements in hard water scale up and can fail sooner, while one used only as a backup can last many years. Titanium and Incoloy elements are often marketed for hard water areas. If an element keeps failing, look at the water hardness and the thermostat rather than just fitting another.